AMS B2x-Fx for active, reactive & apparent energy, multi-tariff, with RTC and data profiles

AMS B2x-Fx for active, reactive & apparent energy, multi-tariff, with RTC and data profiles

Single-phase static meters AMS B2x-Fx measure active, reactive and apparent energy, import/export power, maximum demand, voltage, current and power factor. Data in OBIS-coded registers displayed on LCD in cyclic or step mode.

Product inquiry

Catalogues

Features

  • Measurement of energy, power, voltage, current, power factor ... (+A, -A, +Ri, -Ri, +Rc, -Rc, +R, -R, +S, -S, +P, -P, Pmax, U, I, cos φ...)
  • Historical snapshots of selected registers created at the end of the calendar month - up to 15 monthly records
  • Event logs (magnetic field influence, voltage outages, meter cover tampering...) - number of events with the date of occurrence
  • Data logging in three independent profiles with selectable channels (20 channels)
  • Passive SO transmitting pulse outputs (separate for active and reactive energy)
  • Communication interfaces: optical, RS485 or Mesh with built-in or external antenna (EN 62056-21, mode C)
  • Available with disconnection function via disconnector, relay 1 and relay 2. The disconnection behaviour is defined by modes 0 to 6
  • Welded case on customer request
  • Removable and adjustable top hanger included in the package
  • Complies with IEC/EN 62052-11, IEC/EN 62053-21; EN 50470-1, EN 50470-3 and the requirements of Directive 2014/32/EU (MID) of the European Parliament and of the Council
  • Delivered initially verified for billing measurement of active energy.

Technical data

Accuracy classA, B (MID); 2, 1 (EN 62053-21); 2 and 3 for reactive energy (IEC 62053-23)
Reference voltage [V]220, 230, 240 (-30,+15%)
Nominal frequency [Hz]50 (± 2 %)
Reference current Iref [A]5 and 10
Transitional current Itr [A]0,5 and 1
Starting current Ist [A]≤ 0,02
Minimum current Imin [A]0,25 and 0,5
Maximum current Imax [A]60 (DIN terminal block), 100 (BS term.)
Power consumption - voltage circuit [VA/W]≤ 3,0 / 1,7 (incl. RS 485)
Power consumption - current circuit(s) [VA]≤ 0,02
Operating temperature- 40 °C to + 70 °C
Mean temperature coefficient [%/K]≤ 0,04
Pulse constant for test output kTO [imp/kWh]Configurable: 1 - 30000, preset value: 5000
Mechanical and electromagnetic environmentM1, E2
Terminals current ; voltage ; auxiliary [mm] BS (DIN)ø 8 ; ø 3 ; ø 3 (ø 7 ; ø 3 ; ø 3)
Weight [kg]≤ 0,6
Dimensions - w x h/h´ x d [mm] BS (DIN)130 x 129/190 x 60 (130 x 122/171 x 60)
Mounting hole spacing - w x h [mm] BS (DIN)104 - 112 x 115 - 155 (92 - 112 x 115 - 155)
Protection degreeIP53
ISM - Mesh communication [MHz]868 - 870
Output powerPreset 25,119 mW (14 dBm); optional 1 mW (0 dBm), 10 mW (10 dBm), 25,119 mW (14 dBm); 316,228 mW (25 dBm); 501,187 mW (27 dBm)
ISM Mesh range, line of sight [m]150 for internal antenna; 300 for external antenna
ISM Mesh range indoors with obstacles [m]25 for internal antenna; 50 for external antenna
Number of ISM - Mesh nodes256
RS485 half-duplex - baud rate [Bd]9 600, 19 200
AMS B2x-Fx for active, reactive & apparent energy, multi-tariff, with RTC and data profiles | Applied Meters