AMT B2x-Fx4TxIx (active, reactive & apparent energy), multi-tariff, comm. modules, disconnector

AMT B2x-Fx4TxIx (active, reactive & apparent energy), multi-tariff, comm. modules, disconnector

Three-phase static meters AMT B2x-Fx4TxIx measure active, reactive and apparent electrical energy, instantaneous power, maximum demand, voltage, current and power factor in three-phase four-wire networks. Up to four internal tariff periods or two externally controlled tariffs. Configuration and reading via AMOS optical probe and AMsoft software.

Product inquiry

Catalogues

Features

  • Measurement of energy, power, voltage, current, power factor ... (+A, -A, +Ri, -Ri, +Rc, -Rc, +R, -R, +S, -S, +P, -P, Pmax, U, I, cos φ...)
  • Active energy measurement per phase L1, L2, L3
  • Historical snapshots of selected registers created at the end of the calendar month - up to 15 monthly records
  • Event logs (magnetic field influence, voltage outages, meter cover tampering...) - number of events with the date of occurrence
  • Data logging in three independent profiles P.01, P.02, P.03 with selectable channels (20 channels)
  • Passive SO transmitting pulse outputs (separate for active and reactive energy)
  • Optional disconnector (SCS - Supply Control Switch, meters in case "E" only) and auxiliary relay
  • Welded case on customer request
  • Complies with EN 50470-1, EN 50470-3, EN 62052-11, EN 62052-21, EN 62053-21, EN 62053-23, EN 62054-21, EN 62056-21, EN 62056-6-1, MODBUS and the requirements of Directive 2014/32/EU (MID) of the European Parliament and of the Council
  • Communication interfaces: optical and RS485 (EN 62056-21, mode C), Mesh (only for meters in case "D")
  • Delivered initially verified for billing measurement of active energy.

Technical data

Accuracy class active / reactive energyA, B, (MID), 2, 1, / 3 and 2
Reference voltage [V]3 x 230/400 (-20%,+15%)
Nominal frequency [Hz]50 (± 2 %)
Reference current In / nominal current In [A]5 and 10 /5
Transitional current Itr [A] direct / semi-direct connection0,5 and 1 / 0,25
Starting current Ist [mA]≤ 10
Minimum current Imin [A] direct / semi-direct connection0,25 and 0,5 / 0,05
Maximum current Imax [A] direct / semi-direct connection80 (case D), 100 (case E), 120 (case 9) / 10
Power consumption - voltage circuit [VA/W]Buck source without RS485: 0,88 / 0,33 per phase; Buck source with transformer for RS485 ≤ 2,05 / 1,32 (L1), 0,88 / 0,33 (L2 and L3); MYRRA source (also for RS485) ≤ 1,18 / 0,60 per phase; Buck source with MYRRA for RS485 ≤ 1,42 / 0,55 in L1, 1,10 / 0,40 (L2, L3)
Power consumption - current circuit [VA]≤ 0,01 at In
Pulse constant [imp/kWh] test output kTO / pulse output kSO1000 (adjustable by the manufacturer from 1 to 30000) / 1000 (kTO/x; x = 1 - 10)
Transistor output SO24 V / 30 mA
Operating temperature-40 °C to +70 °C
Mean temperature coefficient [%/K]≤ 0,04
Terminals [mm] current ; voltage ; auxiliary, case 80 A / up to 100 A / up to 120 Aø 7,2 ; ø 3 ; ø 3 / ø 8,2 ; ø 3 ; ø 3 / ø 9,5; ø 3 ; ø 3
Protection degreeIP54 (case E and 9), IP51 (case C and D)
Mounting hole spacing - w x h [mm]150 x 215-230 (case E and 9)
Meter dimensions - w x h/h´ x d [mm]126x135x59 mm (case C and D), 177x251x60 (case E and 9)
Weight [kg]≤ 1,23
AMT B2x-Fx4TxIx (active, reactive & apparent energy), multi-tariff, comm. modules, disconnector | Applied Meters